Weekly Tank Farm Inspection

General Information

Secondary Containment Integrity

Berms, dikes, or retaining walls are intact and structurally sound with no visible cracks, erosion, or settlement *
Containment liner (if applicable) is intact with no tears, punctures, holes, or degradation *
Liner shows no signs of chemical degradation, swelling, or softening from stored product exposure *
Liner/containment materials show no damage from prevailing weather conditions (UV, freeze-thaw, wind) *
Containment area has adequate capacity (100% of largest tank volume + precipitation freeboard) *
No evidence of foundation settling, frost heave, or ground deformation beneath containment *

Containment Area Condition

Containment area is free of debris, trash, tools, and non-essential materials *
Containment area is free of vegetation growth *
Containment area is free of excessive accumulated water, snow, or ice *
No other materials or conditions present that might interfere with the effectiveness of the system *
Access to containment area is unobstructed for inspection and emergency response *

Oil Leak & Spill Check

No visible oil leaks from tanks (shells, bottoms, fittings, valves, or seams) *
No visible oil leaks from piping, connections, hoses, or transfer equipment *
No oil staining, sheens, or spilled product on the ground within or outside the containment area *
No oil sheen or product detected in any accumulated water within containment *
Drip pans and catch basins at fill connections are in place, intact, and emptied as needed *

Drainage Controls

All drain valves are in the closed and locked position *
Drain valves are failsafe design (default to closed on equipment failure) *
Drain valves are operable and in good working condition *
If water was drained this week: water was inspected for oil presence before discharge *
If water was drained this week: drainage operation was documented in the 5-year written record *
No unauthorized discharge of water to land or waters of the state *

Tank Condition & Overfill Prevention

Tank shells show no visible corrosion, dents, bulging, or structural damage *
Tank foundations/supports are stable, level, and free of frost heave or settlement *
Tank vents are clear and unobstructed *
Level gauging devices and liquid level indicators are functional and readable *
Overfill prevention systems (high-level alarms, auto shutoffs) are functional *
Fixed overfill spill containment at each fill connection is intact and functional *
Tank labeling, product identification, and ADEC spill reporting placards are posted and legible *

Piping & Transfer Equipment

All aboveground piping is free of leaks, corrosion, or mechanical damage *
Pipe supports, hangers, and insulation are intact and secure *
All valves are operable and in correct positions (open/closed as required) *
Transfer hoses are in good condition with no cracking, bulging, or coupling damage *
Manifolds not in use are blank flanged or capped *

Safety & Emergency Equipment

Fire extinguishers are present, charged, inspected, and accessible *
Spill response kits are stocked, accessible, and materials are in usable condition *
"No Smoking" and other required warning signs are posted and visible *
ADEC Spill Reporting Placard is posted with current contact information *
Emergency shutoff controls are marked, accessible, and functional *
Area lighting is adequate and in working order (if applicable) *
Security fencing, gates, and locks are intact (if applicable) *

Closeout

Water drained this week?
Sheen present on drain?
Corrective actions needed?
Overall result *